H801RC LED Controller
LPD6803, LPD8806, LPD6812, LPD6813, LPD1882, LPD1889, LPD1883, LPD1886, DMX512, HDMX, APA102, P9813, LD1510, LD1512, LD1530, LD1532, UCS6909, UCS6912, UCS1903, UCS1909, UCS1912, WS2801, WS2803, WS2811, DZ2809, SM16716, TLS3001, TLS3002, TM1812, TM1809, TM1804, TM1803, TM1914, TM1926, TM1829, TM1906, INK1003, BS0825, BS0815, BS0901, LY6620, DM412, DM413, DM114, DM115, DM13C, DM134, DM135, DM136, 74HC595, 6B595, MBI6023, MBI6024, MBI5001, MBI5168, MBI5016, MBI5026, MBI5027, TB62726, TB62706, ST2221A, ST2221C, XLT5026, ZQL9712, ZQL9712HV, etc.
Offline auxiliary software is “LED Build Software”; online auxiliary software is “LED Studio Software”.
(1). Eight output ports drive maximum 8192 pixels. Pixel number that each port can drive is 8192 divided by number of using ports. Port number could be one, two, four, or eight.(means you can choose “one slave with a line”, “four slave with a line”, or “eight slave with a line” in LED Build Software)
(2). Working online or offline, H801RC can be connected to computer, master controller, switch or photoelectric converter.
(3). High synchronization performance, transmission delay of adjacent slave controller is less than 400 ns, image has no tearing or mosaic phenomenon.
(4). Good control effect, gray scale is under precisely control.
(5). Far transmission distance. Data transmitted based on standard Ethernet protocol and the nominal transmission distance between adjacent controllers is up to 100 meters.
(6). Clock scanning frequency is adjustable from 100K to 50M Hz.
(7). Using gray scale and inverse gamma correction technology to make actual displaying effect more consistent with human physiological sensation.
(1). Connect Net1 to the network interface of a computer or a master, and Net2 to Net1 of next H801RC.
(2). Crossover network cable is recommended in engineering. The following is the wiring sequence.
(3). When setting sculpt, you can choose “one line with a slave”, “four line with a slave”, or “eight line with a slave”. Line number is port number.
(4). There are two indicator lights besides the network interfaces, the upper one is green NET, which will flash when H801RC detects data from network cable, the below one is red ACT, which will flash when controller output data to lamp. Flash frequency is effected by data transmit speed.
(5). When H801RC is connected to computer, don’t choose “obtain an IP address automatically” but choose “Use the following IP address”, enter an IP address as follows, Subnet mask is 255.255.255.0, remember check “validate setting upon exit”.
Use optical fiber to prolong transmit distance
Input Voltage |
AC220V |
Power Consumption |
1.5W |
Drive pixels |
8192 |
Weight |
1Kg |
Working Temperature |
-20C°--75C° |
Dimension |
L189 x W123 x H40 |
Installation Hole Distance |
100mm |
Carton Size |